29 C.F.R. § 1926.706

Requirements for masonry construction

Read at: eCFRecfr.gov CornellLII GovInfogovinfo.gov CasesGoogle Scholar

(a) A limited access zone shall be established whenever a masonry wall is being constructed. The limited access zone shall conform to the following.

(1) The limited access zone shall be established prior to the start of construction of the wall.

(2) The limited access zone shall be equal to the height of the wall to be constructed plus four feet, and shall run the entire length of the wall.

(3) The limited access zone shall be established on the side of the wall which will be unscaffolded.

(4) The limited access zone shall be restricted to entry by employees actively engaged in constructing the wall. No other employees shall be permitted to enter the zone.

(5) The limited access zone shall remain in place until the wall is adequately supported to prevent overturning and to prevent collapse unless the height of wall is over eight feet, in which case, the limited access zone shall remain in place until the requirements of paragraph (b) of this section have been met.

(b) All masonry walls over eight feet in height shall be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. The bracing shall remain in place until permanent supporting elements of the structure are in place.

Notes of Decisions
Cited in 2 cases, 2005–2006 · leading case: Fabarc Steel Supply, Inc. v. Composite Constr. Sys., Inc., 914 So. 2d 344 (Ala. 2005).
Fabarc Steel Supply, Inc. v. Composite Constr. Sys., Inc., 914 So. 2d 344 (Ala. 2005). “' 29 CFR 1926.706 (b) (emphasis added). During its construction, the subject wall was supported by scaffolding and gravity, only.”
Pendergrass v. RD Michaels, Inc., 936 So. 2d 684 (Fla. 4th DCA 2006). “See 29 C.F.R. § 1926.706 (a)(4). The job of cleaning up the area so that someone else can brace the walls seems self-evident.”
Annotations are extracted automatically from the opinions in the Syfert caselaw corpus and ranked by authority, recency, and treatment. Dots show Syfertize treatment of the citing case itself.