29 C.F.R. § 1926.910
Inspection after blasting
(a) Immediately after the blast has been fired, the firing line shall be disconnected from the blasting machine, or where power switches are used, they shall be locked open or in the off position.
(b) Sufficient time shall be allowed, not less than 15 minutes in tunnels, for the smoke and fumes to leave the blasted area before returning to the shot. An inspection of the area and the surrounding rubble shall be made by the blaster to determine if all charges have been exploded before employees are allowed to return to the operation, and in tunnels, after the muck pile has been wetted down.
Notes of Decisions
Cited in 1
case, 1974–1974 · leading case: Peter J. Brennan, Sec'y of Labor v. Occupational Saf. & Health Review Comm'n & S. J. Otinger, Jr., Constr. Co., 502 F.2d 30 (5th Cir. 1974).
Peter J. Brennan, Sec'y of Labor v. Occupational Saf. & Health Review Comm'n & S. J. Otinger, Jr., Constr. Co., 502 F.2d 30 (5th Cir. 1974). “” The Safety Regulation allegedly violated, 29 CFR § 1926.910 (b), states, in pertinent part, that '“sufficient time shall be allowed for the smoke and fumes to leave the blasted area before returning to the shot.”
Annotations are extracted automatically from the opinions in the
Syfert caselaw corpus and ranked by authority, recency, and
treatment. Dots show Syfertize treatment of the citing case itself.