21 C.F.R. § 112.55
What microbial standards apply to the treatment processes in § 112.54?
The following microbial standards apply to the treatment processes in § 112.54 as set forth in that section.
(a) For L. monocytogenes,Salmonella species, and E. coli O157:H7, the relevant standards in the table in this paragraph (a); or
| For the microorganism— | The microbial standard is— |
|---|---|
| (1) | Not detected using a method that can detect one colony forming unit (CFU) per 5 gram (or milliliter, if liquid is being sampled) analytical portion. |
| (2) | Not detected using a method that can detect three most probable numbers (MPN) per 4 grams (or milliliter, if liquid is being sampled) of total solids. |
| (3) | Not detected using a method that can detect 0.3 MPN per 1 gram (or milliliter, if liquid is being sampled) analytical portion. |
(b) Salmonella species are not detected using a method that can detect three MPN Salmonella species per 4 grams (or milliliter, if liquid is being sampled) of total solids; and less than 1,000 MPN fecal coliforms per gram (or milliliter, if liquid is being sampled) of total solids.