Table of distances between fireworks process buildings and other specified areas
| Net weight of fireworks 1 (pounds) | Display fireworks 1 (feet) | Consumer fireworks 2 (feet) |
|---|---|---|
| 0-100 | 200 | 25 |
| 101-200 | 200 | 50 |
| 201-300 | 200 | 50 |
| 301-400 | 200 | 50 |
| 401-500 | 200 | 50 |
| Above 500 | Not permitted | Not permitted. |
| 1 Net weight is the weight of all pyrotechnic compositions, and explosive materials and fuse only. | ||
| 2 While consumer fireworks or articles pyrotechnic in a finished state are not subject to regulation, explosive materials used to manufacture or assemble such fireworks or articles are subject to regulation. Thus, fireworks process buildings where consumer fireworks or articles pyrotechnic are being processed shall meet these requirements. | ||
| 3 This table does not apply to the separation distances between fireworks process buildings (see § 555.222) and between magazines (see §§ 555.218 and 555.224). | ||
| 4 The distances in this table apply with or without artificial or natural barricades or screen barricades. However, the use of barricades is highly recommended. | ||
| 5 No work of any kind, except to place or move items other than explosive materials from storage, shall be conducted in any building designated as a warehouse. A fireworks plant warehouse is not subject to § 555.222 or this section, tables of distances. | ||
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.