40 C.F.R. § 434.32
Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)
Except as provided in 40 CFR 125.30-125.32, 40 CFR 401.17, and §§ 434.61, 434.62 and 434.63 of this part, the following limitations establish the concentration or quality of pollutants which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available:
| Pollutant or pollutant property | Maximum for any 1 day | Average of daily values for 30 consecutive days |
|---|---|---|
| Concentration in mg/l | ||
| Iron, total | 7.0 | 3.5 |
| Manganese, total | 4.0 | 2.0 |
| TSS | 70.0 | 35.0 |
| pH | (1) | (1) |
| 1 Within the range 6.0 to 9.0 at all times. | ||
Notes of Decisions
Cited in 2
cases, 1979–2010 · leading case: Consolidation Coal Co. v. Douglas M. Costle, as Adm'r, Env't Prot. Agency, 604 F.2d 239 (4th Cir. 1979).
Consolidation Coal Co. v. Douglas M. Costle, as Adm'r, Env't Prot. Agency, 604 F.2d 239 (4th Cir. 1979). “40 C.F.R. §§ 434.32 (a) and 434.42(a) (footnote 1 to effluent limitations table).”
West Virginia Highlands Conservancy, Inc. v. Huffman, 625 F.3d 159 (4th Cir. 2010). “40 C.F.R. § 434.32 . Based on average daily emissions, these standards require, among other things, a pH level between 6.”
Annotations are extracted automatically from the opinions in the
Syfert caselaw corpus and ranked by authority, recency, and
treatment. Dots show Syfertize treatment of the citing case itself.