42 C.F.R. § 84.157 (2026)
Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements
Edition and currency
Other sources
(a) The static pressure in the facepiece shall not exceed 38 mm. (1.5 inches) of water-column height.
(b) The pressure in the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic feet) per minute.
(c) The exhalation resistance to a flow of air at a rate of 85 liters (3 cubic feet) per minute shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) of water-column height.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.