C.F.R.Title 42Chapter I—Public Health Service, Department of Health and Human ServicesSubchapter G—Occupational Safety and Health Research and Related ActivitiesPart 84—Approval of Respiratory Protective DevicesSubpart J—Supplied-Air Respirators

42 C.F.R. § 84.163 (2026)

Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

(a) The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.

(b) The test will be conducted at the minimum pressure with the maximum hose length and will be repeated at the maximum pressure with the minimum hose length.