Skip to main content
C.F.R.Title 42Chapter I—Public Health Service, Department of Health and Human ServicesSubchapter G—Occupational Safety and Health Research and Related ActivitiesPart 84—Approval of Respiratory Protective DevicesSubpart H—Self-Contained Breathing Apparatus

42 C.F.R. § 84.92 (2026)

Exhalation valve leakage test

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

(a) Dry exhalation valves and valve seats will be subjected to a suction of 25 mm. (1 inch) water-column height while in a normal operating position.

(b) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute.

Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.