46 C.F.R. § 148.51 (2026)
Temperature readings
Edition and currency
Other sources
When Subpart D of this part sets a temperature limit for loading or transporting a material, apply the following rules:
(a) The temperature of the material must be measured 20 to 36 centimeters (8 to 14 inches) below the surface at 3 meter (10 foot) intervals over the length and width of the stockpile or cargo hold.
(b) The temperature must be measured at every spot in the stockpile or cargo hold that shows evidence of heating.
(c) Before loading or transporting the material, all temperatures measured must be below the temperature limit set in Subpart D of this part.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.