46 C.F.R. § 153.371 (2026)
Minimum relief valve setting for refrigerated cargo tanks
Edition and currency
Other sources
The relief valve setting for a containment system that carries a refrigerated cargo must at least equal the lesser of:
(a) That in § 153.370; or
(b) 110 percent of the cargo's vapor pressure at the steady state temperature obtained by a full tank of cargo with the refrigeration system operating under ambient conditions described within the definition of a refrigerated tank in § 153.2.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.