46 C.F.R. § 153.520 (2026)
Special requirements for carbon disulfide
Edition and currency
Other sources
A containment system carrying carbon disulfide must meet the following:
(a) Each cargo pump must be of the intank type and encased within a cylindrical well that extends from the top of the tank to a point no more than 10 cm (approx. 4 in.) above the bottom of the tank.
(b) [Reserved]
(c) The cargo piping and venting systems must be completely independent of those for other cargo.
(d) Pressure relief valves must be made of type 304 or 316 stainless steel.