Skip to main content
C.F.R.Title 46Chapter I—Coast Guard, Department of Homeland SecuritySubchapter O—Certain Bulk Dangerous CargoesPart 154—Safety Standards for Self-Propelled Vessels Carrying Bulk Liquefied GasesSubpart C—Design, Construction and Equipment

46 C.F.R. § 154.451 (2026)

Design vapor pressure

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

The Po (kPa) of an independent tank type C must be calculated by the following formula:

Po = 196 + AC(ρ) 3/2where: A = 1.813 (σm/ΔσA) 2; σm = design primary membrane stress; ΔσA = (allowable dynamic membrane stress for double amplitude at probability level Q = 10−8) 53.9 MPa (7821 psi) for ferritic and martensitic steels and 24.5 MPa (3555 psi) for 5083-0 aluminum; C = a characteristic tank dimension that is the greatest of h, 0.75b, or 0.45 l; where: h = the height of the tank or the dimension in the vessel's vertical direction, in meters; b = the width of the tank or the dimension in the vessel's transverse direction; in meters; and l = the length of the tank or the dimension in the vessel's longitudinal direction, in meters; and ρ = the specific gravity of the cargo.
Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.