Exceptions for compressed gases
(a) The following materials are not subject to the requirements of this subchapter:
(1) Carbonated beverages.
(2) Tires when inflated to pressures not greater than their rated inflation pressures. For transportation by air, tires and tire assemblies must meet the conditions in § 175.8(b)(4) of this subchapter.
(3) Balls used for sports.
(4) Refrigerating machines, including dehumidifiers and air conditioners, and components thereof, such as precharged tubing containing:
(i) 12 kg (25 pounds) or less of a non-flammable, non-toxic gas;
(ii) 12 L (3 gallons) or less of ammonia solution (UN2672);
(iii) Except when offered or transported by air, 12 kg (25 pounds) or less of a flammable, non-toxic gas;
(iv) Except when offered or transported by air or vessel—
(A) 20 kg (44 pounds) or less of a Group A1 refrigerant gas specified in ANSI/ASHRAE Standard 15 (IBR, see § 171.7 of this subchapter); or
(B) 20 kg (44 pounds) or less of a flammable, non-toxic refrigerant gas in Category 1B as classified by the Globally Harmonized System (GHS) of Classification and Labelling of Chemicals (IBR, see § 171.7 of this subchapter), or a Group A2L refrigerant gas as specified in ANSI/ASHRAE Standard 34 (IBR, see § 171.7 of this subchapter); or
(v) 100 g (4 ounces) or less of a flammable, non-toxic liquefied gas.
(5) Manufactured articles or apparatuses, other than light bulbs each containing not more than 100 mg (0.0035 ounce) of inert gas and packaged so that the quantity of inert gas per package does not exceed 1 g (0.035 ounce).
(6) Light bulbs (lamps) conforming to the requirements of § 173.11.
(b) [Reserved]