Pressure and leakage test
(a) Each cargo tank must be tested in accordance with § 178.345-13 and this section.
(b) Pressure test. Test pressure must be as follows:
(1) Using the hydrostatic test method, the test pressure must be at least 1.5 times MAWP.
(2) Using the pneumatic test method, the test pressure must be at least 1.5 times tank MAWP, and the inspection pressure is tank MAWP.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.