Already have an account? Sign in instead.
You stay signed in for 30 days on this browser.
Continue with Google Continue with MicrosoftNo account yet? Create a free one.
We sent a six-digit code.
It expires in ten minutes, works once, and only in this browser. Five wrong tries void it. Send another code.
Your account is live and the Cloudflare checks are off for this browser.
Leakproofness test
(a) General. The leakproofness test must be performed with compressed air or other suitable gases on all packagings intended to contain liquids, except that:
(1) The inner receptacle of a composite packaging may be tested without the outer packaging provided the test results are not affected; and
(2) This test is not required for inner packagings of combination packagings.
(b) Number of packagings to be tested—(1) Production testing. All packagings subject to the provisions of this section must be tested and must pass the leakproofness test:
(i) Before they are first used in transportation; and
(ii) Prior to reuse, when authorized for reuse by § 173.28 of this subchapter.
(2) Design qualification and periodic testing. Three samples of each different packaging must be tested and must pass the leakproofness test. Exceptions for the number of samples used in conducting the leakproofness test are subject to the approval of the Associate Administrator.
(c) Special preparation—(1) For design qualification and periodic testing, packagings must be tested with closures in place. For production testing, packagings need not have their closures in place. Removable heads need not be installed during production testing.
(2) For testing with closures in place, vented closures must either be replaced by similar non-vented closures or the vent must be sealed.
(d) Test method. The packaging must be restrained under water while an internal air pressure is applied; the method of restraint must not affect the results of the test. The test must be conducted, for other than production testing, for a minimum time of five minutes. Other methods, at least equally effective, may be used in accordance with appendix B of this part.
(e) Pressure applied. An internal air pressure (gauge) must be applied to the packaging as indicated for the following packing groups:
(1) Packing Group I: Not less than 30 kPa (4 psi).
(2) Packing Group II: Not less than 20 kPa (3 psi).
(3) Packing Group III: Not less than 20 kPa (3 psi).
(f) Criteria for passing the test. A packaging passes the test if there is no leakage of air from the packaging.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.