49 C.F.R. § 179.301
Individual specification requirements for multi-unit tank car tanks
(a) In addition to § 179.300 the individual specification requirements are as follows:
| DOT specification | 106A500-X | 106A800-X | 110A500-W | 110A600-W | 110A800-W | 110A1000-W |
|---|---|---|---|---|---|---|
| Minimum required bursting pressure, psig | (1) | (1) | 1250 | 1500 | 2000 | 2500 |
| Minimum thickness shell, inches | 13⁄32 | 11⁄16 | 11⁄32 | 3⁄8 | 15⁄32 | 19⁄32 |
| Test pressure, psig (see § 179.300-16) | 500 | 800 | 500 | 600 | 800 | 1000 |
| Safety relief devices, psig (see § 179.300-15) | ||||||
| Start-to-discharge, or burst maximum, p.s.i. | 375 | 600 | 375 | 450 | 600 | 700 |
| Vapor-tight, minimum psig | 300 | 480 | 300 | 360 | 480 | 650 |
| 1 None specified. | ||||||
(b) [Reserved]