What must I do to alleviate interference currents?
(a) For pipelines exposed to stray currents, you must have a program to identify, test for, and minimize the detrimental effects of such currents.
(b) You must design and install each impressed current or galvanic anode system to minimize any adverse effects on existing adjacent metallic structures.