C.F.R. homeSearch C.F.R.
C.F.R.Title 49Chapter II—Federal Railroad Administration, Department of TransportationPart 213—Track Safety StandardsSubpart G—Train Operations at Track Classes 6 and Higher

49 C.F.R. § 213.332 (2026)

Combined track alinement and surface deviations

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

(a) This section applies to any curved track where operations are conducted at a qualified cant deficiency, Eu, greater than 5 inches, and to all Class 9 track, either curved or tangent.

(b) For the conditions defined in paragraph (a) of this section, the combination of alinement and surface deviations for the same chord length on the outside rail in a curve and on any of the two rails of a tangent section, as measured by a TGMS, shall comply with the following formula:

Where— Am = measured alinement deviation from uniformity (outward is positive, inward is negative). AL = allowable alinement limit as per § 213.327(c) (always positive) for the class of track. Sm = measured profile deviation from uniformity (down is positive, up is negative). SL = allowable profile limit as per § 213.331(a) and § 213.331(b) (always positive) for the class of track.[78 FR 16107, Mar. 13, 2013]
Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.

C.F.R. Home  |  Search C.F.R.  |  Search cases for this section  |  syfert.com