C.F.R.Title 49Chapter II—Federal Railroad Administration, Department of TransportationPart 236—Rules, Standards, And Instructions Governing the Installation, Inspection, Maintenance, And Repair of Signal and Train Control Systems, Devices, And AppliancesSubpart E—Automatic Train Stop, Train Control and Cab Signal Systems

49 C.F.R. § 236.552 (2026)

Insulation resistance; requirement

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

When periodic test prescribed in § 236.588 is performed, insulation resistance between wiring and ground of continuous inductive automatic cab signal system, automatic train control system, or automatic train stop system shall be not less than one megohm, and that of an intermittent inductive automatic train stop system, not less than 250,000 ohms. Insulation resistance values between periodic tests shall be not less than 250,000 ohms for a continuous inductive automatic cab signal system, automatic train control system, or automatic train stop system, and 20,000 ohms for an intermittent inductive automatic train stop system.

[49 FR 3387, Jan. 26, 1984]