C.F.R. homeSearch C.F.R.
C.F.R.Title 49Chapter II—Federal Railroad Administration, Department of TransportationPart 238—Passenger Equipment Safety StandardsSubpart H—Specific Requirements for Tier III Passenger Equipment

49 C.F.R. § 238.733 (2026)

Interior fixture attachment

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026

(a) Tier III trainsets shall comply with the interior fixture attachment strength requirements referenced in either of the following paragraphs:

(1) Section 238.233 and APTA PR-CS-S-006-98; or

(2) Section 6.1.4, “Security of furniture, equipment and features,” of GM/RT2100, provided that—

(i) The conditions of § 238.705(b)(2) are met;

(ii) Interior fixture attachment strength is sufficient to resist without failure individually applied loads of 5g longitudinal, 3g lateral, and 3g vertical when applied to the mass of the fixture; and

(iii) Use of the standard is carried out under any conditions identified by the railroad, as approved by FRA.

(b) The standards required in this section are incorporated by reference into this section with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. All approved material is available for inspection at Federal Railroad Administration, Docket Clerk, 1200 New Jersey Avenue SE, Washington, DC and is available from the sources indicated below. It is also available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030 or go to www.archives.gov/federal-register/cfr/ibr-locations.html.

(1) American Public Transportation Association, 1666 K Street NW, Washington, DC 20006, www.aptastandards.com.

(i) APTA PR-CS-S-006-98, Rev. 1, “Standard for Attachment Strength of Interior Fittings for Passenger Railroad Equipment,” Authorized September 28, 2005.

(ii) [Reserved]

(2) Rail Safety and Standards Board Ltd., Communications, RSSB, Block 2 Angel Square, 1 Torrens Street, London, England EC1V 1NY, www.rgsonline.co.uk.

(i) Railway Group Standard GM/RT2100, Issue Four, “Requirements for Rail Vehicle Structures,” December 2010.

(ii) [Reserved]

Enactment and amendments