Skip to main content
Cal. CodesCivil CodeDivision 2. PropertyPart 2. Real or Immovable Property [[755.] - 945.5.]Title 7. Requirements for Actions for Construction Defects

Cal. Civil Code § 896 (2026)

Edition and currency
leginfo export of Nov. 23, 2026: changes through Nov. 11, 2026 (checked Nov. 24, 2026). The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTleginfo export of Nov. 23, 2026: changes through Nov. 11, 2026 (checked Nov. 24, 2026) cited 2003–2024 26citing cases
At a glance

Courts have cited this section in 26 opinions since 2003, 2 of them in the last five years. The most litigated part is subsection (a)(14) (3 cases).

In any action seeking recovery of damages arising out of, or related to deficiencies in, the residential construction, design, specifications, surveying, planning, supervision, testing, or observation of construction, a builder, and to the extent set forth in Chapter 4 (commencing with Section 910), a general contractor, subcontractor, material supplier, individual product manufacturer, or design professional, shall, except as specifically set forth in this title, be liable for, and the claimant’s claims or causes of action shall be limited to violation of, the following standards, except as specifically set forth in this title. This title applies to original construction intended to be sold as an individual dwelling unit. As to condominium conversions, this title does not apply to or does not supersede any other statutory or common law.

(a)With respect to water issues:

(1)A door shall not allow unintended water to pass beyond, around, or through the door or its designed or actual moisture barriers, if any.

(2)Windows, patio doors, deck doors, and their systems shall not allow water to pass beyond, around, or through the window, patio door, or deck door or its designed or actual moisture barriers, including, without limitation, internal barriers within the systems themselves. For purposes of this paragraph, “systems” include, without limitation, windows, window assemblies, framing, substrate, flashings, and trim, if any.

(3)Windows, patio doors, deck doors, and their systems shall not allow excessive condensation to enter the structure and cause damage to another component. For purposes of this paragraph, “systems” include, without limitation, windows, window assemblies, framing, substrate, flashings, and trim, if any.

(4)Roofs, roofing systems, chimney caps, and ventilation components shall not allow water to enter the structure or to pass beyond, around, or through the designed or actual moisture barriers, including, without limitation, internal barriers located within the systems themselves. For purposes of this paragraph, “systems” include, without limitation, framing, substrate, and sheathing, if any.

(5)Decks, deck systems, balconies, balcony systems, exterior stairs, and stair systems shall not allow water to pass into the adjacent structure. For purposes of this paragraph, “systems” include, without limitation, framing, substrate, flashing, and sheathing, if any.

(6)Decks, deck systems, balconies, balcony systems, exterior stairs, and stair systems shall not allow unintended water to pass within the systems themselves and cause damage to the systems. For purposes of this paragraph, “systems” include, without limitation, framing, substrate, flashing, and sheathing, if any.

(7)Foundation systems and slabs shall not allow water or vapor to enter into the structure so as to cause damage to another building component.

(8)Foundation systems and slabs shall not allow water or vapor to enter into the structure so as to limit the installation of the type of flooring materials typically used for the particular application.

(9)Hardscape, including paths and patios, irrigation systems, landscaping systems, and drainage systems, that are installed as part of the original construction, shall not be installed in such a way as to cause water or soil erosion to enter into or come in contact with the structure so as to cause damage to another building component.

(10)Stucco, exterior siding, exterior walls, including, without limitation, exterior framing, and other exterior wall finishes and fixtures and the systems of those components and fixtures, including, but not limited to, pot shelves, horizontal surfaces, columns, and plant-ons, shall be installed in such a way so as not to allow unintended water to pass into the structure or to pass beyond, around, or through the designed or actual moisture barriers of the system, including any internal barriers located within the system itself. For purposes of this paragraph, “systems” include, without limitation, framing, substrate, flashings, trim, wall assemblies, and internal wall cavities, if any.

(11)Stucco, exterior siding, and exterior walls shall not allow excessive condensation to enter the structure and cause damage to another component. For purposes of this paragraph, “systems” include, without limitation, framing, substrate, flashings, trim, wall assemblies, and internal wall cavities, if any.

(12)Retaining and site walls and their associated drainage systems shall not allow unintended water to pass beyond, around, or through its designed or actual moisture barriers including, without limitation, any internal barriers, so as to cause damage. This standard does not apply to those portions of any wall or drainage system that are designed to have water flow beyond, around, or through them.

(13)Retaining walls and site walls, and their associated drainage systems, shall only allow water to flow beyond, around, or through the areas designated by design.

(14)The lines and components of the plumbing system, sewer system, and utility systems shall not leak.

(15)Plumbing lines, sewer lines, and utility lines shall not corrode so as to impede the useful life of the systems.

(16)Sewer systems shall be installed in such a way as to allow the designated amount of sewage to flow through the system.

(17)Showers, baths, and related waterproofing systems shall not leak water into the interior of walls, flooring systems, or the interior of other components.

(18) The waterproofing system behind or under ceramic tile and tile countertops shall not allow water into the interior of walls, flooring systems, or other components so as to cause damage. Ceramic tile systems shall be designed and installed so as to deflect intended water to the waterproofing system.

(b)With respect to structural issues:

(1)Foundations, load bearing components, and slabs, shall not contain significant cracks or significant vertical displacement.

(2)Foundations, load bearing components, and slabs shall not cause the structure, in whole or in part, to be structurally unsafe.

(3)Foundations, load bearing components, and slabs, and underlying soils shall be constructed so as to materially comply with the design criteria set by applicable government building codes, regulations, and ordinances for chemical deterioration or corrosion resistance in effect at the time of original construction.

(4)A structure shall be constructed so as to materially comply with the design criteria for earthquake and wind load resistance, as set forth in the applicable government building codes, regulations, and ordinances in effect at the time of original construction.

(c)With respect to soil issues:

(1)Soils and engineered retaining walls shall not cause, in whole or in part, damage to the structure built upon the soil or engineered retaining wall.

(2)Soils and engineered retaining walls shall not cause, in whole or in part, the structure to be structurally unsafe.

(3)Soils shall not cause, in whole or in part, the land upon which no structure is built to become unusable for the purpose represented at the time of original sale by the builder or for the purpose for which that land is commonly used.

(d)With respect to fire protection issues:

(1)A structure shall be constructed so as to materially comply with the design criteria of the applicable government building codes, regulations, and ordinances for fire protection of the occupants in effect at the time of the original construction.

(2)Fireplaces, chimneys, chimney structures, and chimney termination caps shall be constructed and installed in such a way so as not to cause an unreasonable risk of fire outside the fireplace enclosure or chimney.

(3)Electrical and mechanical systems shall be constructed and installed in such a way so as not to cause an unreasonable risk of fire.

(e)With respect to plumbing and sewer issues:

Plumbing and sewer systems shall be installed to operate properly and shall not materially impair the use of the structure by its inhabitants. However, no action may be brought for a violation of this subdivision more than four years after close of escrow.

(f)With respect to electrical system issues:

Electrical systems shall operate properly and shall not materially impair the use of the structure by its inhabitants. However, no action shall be brought pursuant to this subdivision more than four years from close of escrow.

(g)With respect to issues regarding other areas of construction:

(1)Exterior pathways, driveways, hardscape, sidewalls, sidewalks, and patios installed by the original builder shall not contain cracks that display significant vertical displacement or that are excessive. However, no action shall be brought upon a violation of this paragraph more than four years from close of escrow.

(2)Stucco, exterior siding, and other exterior wall finishes and fixtures, including, but not limited to, pot shelves, horizontal surfaces, columns, and plant-ons, shall not contain significant cracks or separations.

(3)(A)To the extent not otherwise covered by these standards, manufactured products, including, but not limited to, windows, doors, roofs, plumbing products and fixtures, fireplaces, electrical fixtures, HVAC units, countertops, cabinets, paint, and appliances shall be installed so as not to interfere with the products’ useful life, if any.

(B)For purposes of this paragraph, “useful life” means a representation of how long a product is warranted or represented, through its limited warranty or any written representations, to last by its manufacturer, including recommended or required maintenance. If there is no representation by a manufacturer, a builder shall install manufactured products so as not to interfere with the product’s utility.

(C)For purposes of this paragraph, “manufactured product” means a product that is completely manufactured offsite.

(D)If no useful life representation is made, or if the representation is less than one year, the period shall be no less than one year. If a manufactured product is damaged as a result of a violation of these standards, damage to the product is a recoverable element of damages. This subparagraph does not limit recovery if there has been damage to another building component caused by a manufactured product during the manufactured product’s useful life.

(E)This title does not apply in any action seeking recovery solely for a defect in a manufactured product located within or adjacent to a structure.

(4)Heating shall be installed so as to be capable of maintaining a room temperature of 70 degrees Fahrenheit at a point three feet above the floor in any living space if the heating was installed pursuant to a building permit application submitted prior to January 1, 2008, or capable of maintaining a room temperature of 68 degrees Fahrenheit at a point three feet above the floor and two feet from exterior walls in all habitable rooms at the design temperature if the heating was installed pursuant to a building permit application submitted on or before January 1, 2008.

(5)Living space air-conditioning, if any, shall be provided in a manner consistent with the size and efficiency design criteria specified in Title 24 of the California Code of Regulations or its successor.

(6)Attached structures shall be constructed to comply with interunit noise transmission standards set by the applicable government building codes, ordinances, or regulations in effect at the time of the original construction. If there is no applicable code, ordinance, or regulation, this paragraph does not apply. However, no action shall be brought pursuant to this paragraph more than one year from the original occupancy of the adjacent unit.

(7)Irrigation systems and drainage shall operate properly so as not to damage landscaping or other external improvements. However, no action shall be brought pursuant to this paragraph more than one year from close of escrow.

(8)Untreated wood posts shall not be installed in contact with soil so as to cause unreasonable decay to the wood based upon the finish grade at the time of original construction. However, no action shall be brought pursuant to this paragraph more than two years from close of escrow.

(9)Untreated steel fences and adjacent components shall be installed so as to prevent unreasonable corrosion. However, no action shall be brought pursuant to this paragraph more than four years from close of escrow.

(10)Paint and stains shall be applied in such a manner so as not to cause deterioration of the building surfaces for the length of time specified by the paint or stain manufacturers’ representations, if any. However, no action shall be brought pursuant to this paragraph more than five years from close of escrow.

(11)Roofing materials shall be installed so as to avoid materials falling from the roof.

(12)The landscaping systems shall be installed in such a manner so as to survive for not less than one year. However, no action shall be brought pursuant to this paragraph more than two years from close of escrow.

(13)Ceramic tile and tile backing shall be installed in such a manner that the tile does not detach.

(14)Dryer ducts shall be installed and terminated pursuant to manufacturer installation requirements. However, no action shall be brought pursuant to this paragraph more than two years from close of escrow.

(15)Structures shall be constructed in such a manner so as not to impair the occupants’ safety because they contain public health hazards as determined by a duly authorized public health official, health agency, or governmental entity having jurisdiction. This paragraph does not limit recovery for any damages caused by a violation of any other paragraph of this section on the grounds that the damages do not constitute a health hazard.

The 20 cases that cite Cal. Civil Code § 896 most heavily, weighted by court and treatment. RelevanceNewestTreatment
1
GREENAcqua Vista Homeowners Assn. v. MWI, Inc., 7 Cal. App. 5th 1129 (Ct. App. 2017).
cites § 896 39×cited by 24 cases
Where it cites § 896
“6 The third amended complaint alleged a cause of action styled as “Violation of SB800[ 7 ] Construction Standards, Civil Code § 896” against all defendants, including MWI.”
Later courts cite it for
“we first examine the words themselves because the statutory language is generally the most reliable indicator of legislative intent. the words of the statute should be given their ordinary and usual meaning and should be construed in their statutory context.” · 2 citing courts
2
GREENLiberty Mut. Ins. v. Brookfield Crystal Cove LLC, 219 Cal. App. 4th 98 (Ct. App. 2013).
cites § 896 10×cited by 8 cases
Where it cites § 896
“) Finally, Civil Code section 896 provides, in relevant part: “In any action seeking recovery of damages arising out of, or related to deficiencies in, the residential construction, design, specifications, surveying, planning, supervision, testing, or observation of…”
3
GREENBruni v. Didion, 160 Cal. App. 4th 1272 (Ct. App. 2008).
cites § 896 2×cited by 92 cases
Where it cites § 896
“In addition, they asserted statutory causes of action based on Business and Professions Code sections 7031 (unlicensed contractor), 17200 (unfair competition), and 17500 (false advertising) and Civil Code section 896 (building standards for new homes).”
The case’s holding
A court must decide whether a party agreed to be bound by an arbitration clause before compelling arbitration when the challenge concerns contract formation.
Later courts cite it for
“because the parties are the masters of their collective fate, they can agree to arbitrate almost any dispute - even a dispute over whether the underlying dispute is subject to arbitration.” · 4 citing courts
cites § 896 2×cited by 76 cases
Where it cites § 896
“(Civ. Code, § 896; see id., § 936; all undesignated subsequent statutory references are to this code.”
The case’s holding
The application of factors to determine the existence of a duty of care depends on the specific circumstances of each case (Biakanja v. Irving).
Later courts cite it for
“actionable negligence involves a legal duty to use due care, a breach of such legal duty, and the breach as the proximate or legal cause of the resulting injury.” · 10 citing courts
5
GREENBurch v. Superior Court, 223 Cal. App. 4th 1411 (Ct. App. 2014).
cites § 896 4×cited by 15 cases
Where it cites § 896
“At the hearing on the motions, the court cited Civil Code sections 896 and 943 in support of its ruling.”
Later courts cite it for
“summary adjudication of a cause of action is appropriate only if there is no triable issue of material fact as to that cause of action and the moving party is entitled to judgment on the cause of action as a matter of law.” · 4 citing courts
6
GREENOscar Ortega v. Uponor, Inc., 716 F.3d 1057 (8th Cir. 2013).
cites § 896 2×subsections: (a)(15) 2×cited by 38 cases
Where it cites § 896
“He claimed that he had not received “any notice whatsoever” concerning the class action, and argued that his interests were “not adequately represented by the existing parties” because they had failed to assert a viable claim under California’s Right of Repair Act, Cal. Civ.Code…”
The case’s holding
A district court determines the fairness of a class action settlement by evaluating the merits of the case, the defendant's financial condition, the complexity of litigation, and the opposition.
Later courts cite it for
“a settlement agreement is 'presumptively valid.” · 2 citing courts
7
GREENMcCaffrey Grp., Inc. v. Superior Court, 224 Cal. App. 4th 1330 (Ct. App. 2014).
cites § 896 2×cited by 25 cases
Where it cites § 896
“Article 7 of the CC&Rs provides, in part, that any claim, dispute or controversy between any owner and McCaffrey relating to the CC&Rs or the use or condition of any lot, including claims made under Civil Code section 896 or 897, shall be subject to the claims procedures set…”
8
NEUTRALCentex Homes v. Superior Court, 214 Cal. App. 4th 1090 (Ct. App. 2013).
cites § 896 24×cited by 4 cases
Where it cites § 896
“) In this case, we must determine whether the trial court properly concluded that a homeowners association’s original complaint against Centex Homes (Centex) 2 alleging violations of various statutory building standards (Civ. Code, § 896) related to Centex’s construction of a…”
9
GREENStewart v. Electrolux Home Prods., Inc., 304 F. Supp. 3d 894 (E.D. Cal. 2018).
cites § 896 1×cited by 31 cases
Where it cites § 896
“They allege only that the Sears repairperson told them not to engage the self-cleaning function again. (Cmplt., ¶¶ 23, 26.) The allegations about the nature of the purported defect and the potential damages and safety risks associated with the defect are not consistent between…”
The case’s holding
Consumer warranty claims are subject to privity requirements, and courts disagree whether a third-party beneficiary exception to privity applies in California consumer warranty cases.
Later courts cite it for
“district courts in california are split on a third-party beneficiary exception to privity in the consumer warranty context.” · 2 citing courts
10
NO FLAGLantzy v. Centex Homes, 31 Cal. 4th 363 (2003).
cites § 896 2×cited by 254 cases
Where it cites § 896
“) The new law sets detailed quality and performance standards for new residential construction and provides that a homeowner may sue for (1) specific violations of the statutory standards (Civ. Code, § 896) and (2) any other “function or component of [the] structure,” to the…”
11
GREENGeorge v. Uponor Corp., 988 F. Supp. 2d 1056 (D. Minn. 2013).
cites § 896 2×subsections: (a)(15) 2×cited by 12 cases
Where it cites § 896
“Plaintiffs also state several claims on behalf of putative state subclasses, for: (7) violation of the New Mexico Unfair Practices Act; (8) violation of the Arizona Consumer Fraud Act; (9) violation of the standards for residential construction under California Civil Code §…”
12
GREENThompson v. Toll Dublin, LLC, 165 Cal. App. 4th 1360 (Ct. App. 2008).
cites § 896 1×cited by 10 cases
Where it cites § 896
“tractual or tort, including, but not limited to, the purchase, sale, condition, design, construction or materials used in construction of any portion of the Project, the agreement between Declarant [and] Owner to purchase a Condominium or any related agreement, any Claimed Title…”
Later courts cite it for
“the strong policy in favor of arbitration may not be used to permit a party to enforce provisions of an arbitration agreement that, as here, either do not exist or were so poorly drafted that another party cannot be presumed to have agreed to them.” · 3 citing courts
13
GREENLantzy v. Centex Homes, 31 Cal. 4th 363 (2003).
cites § 896 4×cited by 1 case
Where it cites § 896
“) The new law sets detailed quality and performance standards for new residential construction and provides that a homeowner may sue for (1) specific violations of the statutory standards (Civ.Code, § 896) and (2) any other "function or component of [the] structure," to the…”
The case’s holding
Courts may apply equitable tolling in specific situations to prevent unjust technical forfeiture of causes of action when the defendant suffers no prejudice (equitable tolling).
Later courts cite it for
“to prevent the unjust technical forfeiture of causes of action, where the defendant would suffer no prejudice.” · 11 citing courts
14
NO FLAGBrasch v. K. Hovnanian Enter., Inc., No. G057436 (Cal. Ct. App. Aug. 27, 2020).
cites § 896 23×subsections: (a)(14)unpublished
Where it cites § 896
“Common questions of law and facts alleged included, among others: whether the copper pipe was defective for the water conditions in the area; whether defendants had notice, and to what degree, of those conditions; whether section 896, subdivision (a)(14) or (15) was violated by…”
15
NO FLAGSmith v. Pulte Home Corp., No. G057435 (Cal. Ct. App. Aug. 28, 2020).
cites § 896 21×subsections: (a)(14)unpublished
Where it cites § 896
“Common questions of law and facts alleged included, among others: whether the copper pipe was defective for the water conditions in the area; whether defendant had notice, and to what degree, of those conditions; whether section 896, subdivision (a)(14) or (15) was violated by…”
16
NEUTRALState Farm Gen. Ins. Co. v. Oetiker, Inc., 58 Cal. App. 5th 940 (Ct. App. 2020).
cites § 896 30×subsections: (a)(14) (g)(3)(E)
Where it cites § 896
“(§ 896, subd. (g)(3)(E).) The trial court granted Oetiker’s motion for summary judgment.”
17
NO FLAGMcMillin Albany LLC v. Super. Ct., No. F069370 (Cal. Ct. App. Aug. 26, 2015).
cites § 896 27×
Where it cites § 896
“The trial court denied McMillin’s motion for a stay, stating: “Pursuant to Liberty Mutual …, the Plaintiffs are entitled to plead common law causes of action in lieu of a cause of action for violation of building standards set forth in Civil Code § 896 et seq.”
18
GREENGeorge v. Uponor, Inc., 290 F.R.D. 574 (D. Minn. 2013).
cites § 896 1×cited by 1 case
Where it cites § 896
“; see also Cal. Civ.Code § 896 (2013). The Court denied Ortega’s motion to intervene, finding the motion untimely, prejudicial to the parties, and unnecessary because the proposed settlement classes sufficiently addressed Ortega’s concerns.”
19
NO FLAGO'Toole v. Oceanview Cottages, No. D080948 (Cal. Ct. App. Oct. 28, 2024).
cites § 896 4×unpublished
Where it cites § 896
“Relevant here, the statement of claims submitted for adjudication included claims for (1) negligence, (2) violation of the building standards set forth in Civil Code section 896,2 (3) negligent misrepresentation, (4) intentional misrepresentation, and (5) concealment.”
20
GREENAldea Dos Vientos v. CalAtlantic Grp., Inc., 44 Cal. App. 5th 1073 (Ct. App. 2020).
cites § 896 1×cited by 2 cases
Where it cites § 896
“Code, §§ 896 [listing construction defects for which the developer is liable]; 897 [developer liable for defects not expressly listed]; 941, subd (a) [10-year statute of limitations on actions for construction defects].”

Show all 26 citing cases (list view) →

The flag is Syfertize’s treatment of the citing case itself, not of the statute. “Where it cites” is the passage in the opinion; the holding is a summary of the whole case and may concern another point. Annotations are extracted automatically from the opinions in the Syfert caselaw corpus.

Citing cases by year
200320132024

One bar per year. Tallest: 8 cases in 2013. These are opinions in the Syfert collection, which holds more of some courts’ recent opinions than their older ones, so a rise can reflect what the collection holds and not more litigation.

By court
Cal. Ct. App.18Cal.3E.D. Cal.2D. Minn.28th Cir.1
By subsection
(a)(14)3 cases
Brasch v. K. Hovnanian Enter., Inc., No. G057436 (Cal. Ct. App. Aug. 27, 2020).“Common questions of law and facts alleged included, among others: whether the copper pipe was defective for the water conditions in the area; whether defendants had notice, and to what degree, of those conditions; whether section 896, subdivision (a)(14) or (15) was violated by…”
Smith v. Pulte Home Corp., No. G057435 (Cal. Ct. App. Aug. 28, 2020).“Common questions of law and facts alleged included, among others: whether the copper pipe was defective for the water conditions in the area; whether defendant had notice, and to what degree, of those conditions; whether section 896, subdivision (a)(14) or (15) was violated by…”
State Farm Gen. Ins. Co. v. Oetiker, Inc., 58 Cal. App. 5th 940 (Ct. App. 2020).“(§ 896, subd. (g)(3)(E).) The trial court granted Oetiker’s motion for summary judgment.”
(a)(15)2 cases
Oscar Ortega v. Uponor, Inc., 716 F.3d 1057 (8th Cir. 2013).“He claimed that he had not received “any notice whatsoever” concerning the class action, and argued that his interests were “not adequately represented by the existing parties” because they had failed to assert a viable claim under California’s Right of Repair Act, Cal. Civ.Code…”
George v. Uponor Corp., 988 F. Supp. 2d 1056 (D. Minn. 2013).“Plaintiffs also state several claims on behalf of putative state subclasses, for: (7) violation of the New Mexico Unfair Practices Act; (8) violation of the Arizona Consumer Fraud Act; (9) violation of the standards for residential construction under California Civil Code §…”
(g)(3)(E)1 case
State Farm Gen. Ins. Co. v. Oetiker, Inc., 58 Cal. App. 5th 940 (Ct. App. 2020).

Show all 26 citing cases (list view) →

Enactment and amendments
Amended by Stats. 2012, Ch. 770, Sec. 2. (AB 2697) Effective January 1, 2013.
Versions

Edition shown: leginfo export of Nov. 23, 2026: changes through Nov. 11, 2026 (checked Nov. 24, 2026). Syfert holds no earlier or later version of this section.