16 C.F.R. § 1615.3

General requirements

Read at: eCFRecfr.gov CornellLII GovInfogovinfo.gov CasesGoogle Scholar

(a) Summary of test method. Five conditioned specimens, 8.9 × 25.4 cm. (3.5 × 10 in.), are suspended one at a time vertically in holders in a prescribed cabinet and subjected to a standard flame along their bottom edge for a specified time under controlled conditions. The char length is measured.

(b) Test criteria. The test criteria when the testing is done in accordance with § 1615.4 Test procedure are:

(1) Average char length. The average char length of five specimens shall not exceed 17.8 cm. (7.0 in.).

(2) Full specimen burn. No individual specimen shall have a char length of 25.4 cm. (10 in.).

[40 FR 59903, Dec. 30, 1975, as amended at 43 FR 4853, Feb. 6, 1978]
Notes of Decisions
Cited in 1 case, 1983–1983 · leading case: United States v. Sun & Sand Imports, Ltd., 564 F. Supp. 1402 (S.D.N.Y. 1983).
United States v. Sun & Sand Imports, Ltd., 564 F. Supp. 1402 (S.D.N.Y. 1983). “§§ 1191-1204 (“FFA”) as set forth in 16 C.F.R. § 1615.3 et seq. (1982) (the “flammability standard”).”
Annotations are extracted automatically from the opinions in the Syfert caselaw corpus and ranked by authority, recency, and treatment. Dots show Syfertize treatment of the citing case itself.