Skip to main content
C.F.R.Title 21Chapter I—Food and Drug Administration, Department of Health and Human ServicesSubchapter F—BiologicsPart 606—Current Good Manufacturing Practice for Blood and Blood ComponentsSubpart A—General Provisions

21 C.F.R. § 606.3 (2026)

Definitions

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026 cited 1985–1991 2citing cases
At a glance

Courts have cited this section in 2 opinions since 1985.

As used in this part:

(a) Blood means a product that is a fluid containing dissolved and suspended elements which was collected from the vascular system of a human.

(b) Unit means the volume of blood or one of its components in a suitable volume of anticoagulant obtained from a single collection of blood from one donor.

(c) Blood component means a product containing a part of human blood separated by physical or mechanical means.

(d) Plasma for further manufacturing means that liquid portion of blood separated and used as material to prepare another product.

(e) Plasmapheresis means the procedure in which blood is removed from the donor, the plasma is separated from the formed elements and at least the red blood cells are returned to the donor.

(f) Plateletpheresis means the procedure in which blood is removed from a donor, a platelet concentrate is separated, and the remaining formed elements are returned to the donor along with a portion of the residual plasma.

(g) Leukapheresis means the procedure in which blood is removed from the donor, a leukocyte concentrate is separated, and the remaining formed elements and residual plasma are returned to the donor.

(h) Facilities means any area used for the collection, processing, compatibility testing, storage or distribution of blood and blood components.

(i) Processing means any procedure employed after collection, and before or after compatibility testing of blood, and includes the identification of a unit of donor blood, the preparation of components from such unit of donor blood, serological testing, labeling and associated recordkeeping.

(j) Compatibility testing means the procedures performed to establish the matching of a donor's blood or blood components with that of a potential recipient.

(k) Distributed means:

(1) The blood or blood components have left the control of the licensed manufacturer, unlicensed registered blood establishment, or transfusion service; or

(2) The licensed manufacturer has provided Source Plasma or any other blood component for use in the manufacture of a licensed biological product.

(l) Control means having responsibility for maintaining the continued safety, purity, and potency of the product and for compliance with applicable product and establishment standards, and for compliance with current good manufacturing practices.

[40 FR 53532, Nov. 18, 1975, as amended at 64 FR 45370, Aug. 19, 1999; 65 FR 66635, Nov. 7, 2000; 66 FR 1835, Jan. 10, 2001; 66 FR 40889, Aug. 6, 2001; 72 FR 45886, Aug. 16, 2007; 80 FR 29894, May 22, 2015]
The 2 cases that cite 21 C.F.R. § 606.3 most heavily, weighted by court and treatment. RelevanceNewestTreatment
cites § 606.3 1×cited by 1,351 cases
Where it cites § 606.3
“Under this procedure, whole blood removed from the donor is separated into plasma and other components, and “at least the red blood cells are returned to the donor,” 21 CFR § 606.3 (e) (1984). Appellee sells the plasma to pharmaceutical manufacturers.”
The case’s holding
Local health and safety regulations are not preempted by federal law unless there is a clear indication of congressional intent or a direct conflict with federal objectives.
Later courts cite it for
“invalidates state laws that 'interfere with, or are contrary to,' federal law.” · 83 citing courts
2
GREENSmith v. Cutter Biological, Inc., 823 P.2d 717 (Haw. 1991).
cites § 606.3 2×cited by 41 cases
Where it cites § 606.3
“" 21 C.F.R. § 606.3 (c) (1990). [7] Factor VIII is a blood protein, essential for normal coagulation, which can be extracted from human blood.”
The case’s holding
A plaintiff may recover damages under the alternative market share theory of liability in negligence actions when the actual tortfeasor cannot be identified.
Later courts cite it for
“the alternative market share theory of recovery.” · 1 citing court

The flag is Syfertize’s treatment of the citing case itself, not of the statute. “Where it cites” is the passage in the opinion; the holding is a summary of the whole case and may concern another point. Annotations are extracted automatically from the opinions in the Syfert caselaw corpus.

By subsection

Courts have not cited this section by subsection, so its cases are not split up here. The Leading cases tab lists the cases that cite it most heavily.

Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.