24 C.F.R. § 3280.11 (2026)
Certification label
Edition and currency
Other sources
Courts have cited this section in 4 opinions since 2003, 1 of them in the last five years.
(a) A permanent label shall be affixed to each transportable section of each manufactured home for sale or lease in the United States. This label shall be separate and distinct from the data plate which the manufacturer is required to provide under § 3280.5 of the standards.
(b) The label shall be approximately 2 in. by 4 in. in size and shall be permanently attached to the manufactured home by means of 4 blind rivets, drive screws, or other means that render it difficult to remove without defacing it. It shall be etched on 0.32 in. thick aluminum plate. The label number shall be etched or stamped with a 3 letter designation which identifies the production inspection primary inspection agency and which the Secretary shall assign. Each label shall be marked with a 6 digit number which the label supplier shall furnish. The labels shall be stamped with numbers sequentially.
(c) The label shall read as follows:
As evidenced by this label No. ABC 000001, the manufacturer certifies to the best of the manufacturer's knowledge and belief that this manufactured home has been inspected in accordance with the requirements of the Department of Housing and Urban Development and is constructed in conformance with the Federal manufactured home construction and safety standards in effect on the date of manufacture. See date plate.
(d) The label must be located at the taillight end of each transportable section of the manufactured home approximately 1 foot up from the floor and 1 foot in from the road side, or as near that location on a permanent part of the exterior of the manufactured home section as practicable. The road side is the right side of the manufactured home when one views the manufactured home from the tow bar end of the manufactured home. If locating the label on the taillight end of a transportable section will prevent the label from being visible after the manufactured home section is installed at the installation site, the label must be installed on a permanent part of the exterior of the manufactured home section, in a visible location as specified in the approved design.
- Summary
- No passage or summary on file for this case yet.
- Where it cites § 3280.11
- “24 CFR 3280.11.... The HUD Code also has a series of requirements for the design and construction of the home.”
- Where it cites § 3280.11
- “24 C.F.R. § 3280.11 (describing certification label); see generally 42 U.”
- Where it cites § 3280.11
- “§ 5415 ; 24 C.F.R. 3280.11. The State of Texas, in turn, has its own body of law that governs HUD compliance in the context of manufactured homes.”
The flag is Syfertize’s treatment of the citing case itself, not of the statute. “Where it cites” is the passage in the opinion; the holding is a summary of the whole case and may concern another point. Annotations are extracted automatically from the opinions in the Syfert caselaw corpus.
One bar per year. Tallest: 1 case in 2003. These are opinions in the Syfert collection, which holds more of some courts’ recent opinions than their older ones, so a rise can reflect what the collection holds and not more litigation.
Courts have not cited this section by subsection, so its cases are not split up here. The Leading cases tab lists the cases that cite it most heavily.
Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.
Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.