(a) Firing of sewage sludge in a sewage sludge incinerator shall not violate the requirements in the National Emission Standard for Beryllium in subpart C of 40 CFR part 61.

(b) Firing of sewage sludge in a sewage sludge incinerator shall not violate the requirements in the National Emission Standard for Mercury in subpart E of 40 CFR part 61.

(c) Pollutant limit—lead. (1) The average daily concentration for lead in sewage sludge fed to a sewage sludge incinerator shall not exceed the concentration calculated using Equation (4).

Where: C = Average daily concentration of lead in sewage sludge. NAAQS = National Ambient Air Quality Standard for lead in micrograms per cubic meter. DF = Dispersion factor in micrograms per cubic meter per gram per second. CE = Sewage sludge incinerator control efficiency for lead in hundredths. SF = Sewage sludge feed rate in metric tons per day (dry weight basis).

(2) The dispersion factor (DF) in equation (4) shall be determined from an air dispersion model in accordance with § 503.43(e).

(i) When the sewage sludge stack height is 65 meters or less, the actual sewage sludge incinerator stack height shall be used in the air dispersion model to determine the dispersion factor (DF) for equation (4).

(ii) When the sewage sludge incinerator stack height exceeds 65 meters, the creditable stack height shall be determined in accordance with 40 CFR 51.100(ii) and the creditable stack height shall be used in the air dispersion model to determine the dispersion factor (DF) for equation (4).

(3) The control efficiency (CE) for equation (4) shall be determined from a performance test of the sewage sludge incinerator in accordance with § 503.43(e).

(d) Pollutant limit—arsenic, cadmium, chromium, and nickel. (1) The average daily concentration for arsenic, cadmium, chromium, and nickel in sewage sludge fed to a sewage sludge incinerator each shall not exceed the concentration calculated using equation (5).

Where: C = Average daily concentration of arsenic, cadmium, chromium, or nickel in sewage sludge. CE = Sewage sludge incinerator control efficiency for arsenic, cadmium, chromium, or nickel in hundredths. DF = Dispersion factor in micrograms per cubic meter per gram per second. RSC = Risk specific concentration for arsenic, cadmium, chromium, or nickel in micrograms per cubic meter. SF = Sewage sludge feed rate in metric tons per day (dry weight basis).

(2) The risk specific concentrations for arsenic, cadmium, and nickel used in equation (5) shall be obtained from Table 1 of § 503.43.

Table 1 of § 503.43—Risk Specific Concentration for Arsenic, Cadmium, and Nickel

PollutantRisk specific concentration (micrograms per cubic meter)
Arsenic0.023
Cadmium0.057
Nickel2.0

(3) The risk specific concentration for chromium used in equation (5) shall be obtained from Table 2 of § 503.43 or shall be calculated using equation (6).

Table 2 of § 503.43—Risk Specific Concentration For Chromium

Type of IncineratorRisk specific concentration (micrograms per cubic meter)
Fluidized bed with wet scrubber0.65
Fluidized bed with wet scrubber and wet electrostatic precipitator0.23
Other types with wet scrubber0.064
Other types with wet scrubber and wet electrostatic precipitator0.016
Where: RSC = risk specific concentration for chromium in micrograms per cubic meter used in equation (5). r = decimal fraction of the hexavalent chromium concentration in the total chromium concentration measured in the exit gas from the sewage sludge incinerator stack in hundredths.

(4) The dispersion factor (DF) in equation (5) shall be determined from an air dispersion model in accordance with § 503.43(e).

(i) When the sewage sludge incinerator stack height is equal to or less than 65 meters, the actual sewage sludge incinerator stack height shall be used in the air dispersion model to determine the dispersion factor (DF) for equation (5).

(ii) When the sewage sludge incinerator stack height is greater than 65 meters, the creditable stack height shall be determined in accordance with 40 CFR 51.100(ii) and the creditable stack height shall be used in the air dispersion model to determine the dispersion factor (DF) for equation (5).

(5) The control efficiency (CE) for equation (5) shall be determined from a performance test of the sewage sludge incinerator in accordance with § 503.43(e).

(e) Air dispersion modeling and performance testing. (1) The air dispersion model used to determine the dispersion factor in § 503.43 (c)(2) and (d)(4) shall be appropriate for the geographical, physical, and population characteristics at the sewage sludge incinerator site. The performance test used to determine the control efficiencies in § 503.43 (c)(3) and (d)(5) shall be appropriate for the type of sewage sludge incinerator.

(2) For air dispersion modeling initiated after September 3, 1999, the modeling results shall be submitted to the permitting authority 30 days after completion of the modeling. In addition to the modeling results, the submission shall include a description of the air dispersion model and the values used for the model parameters.

(3) The following procedures, at a minimum, shall apply in conducting performance tests to determine the control efficiencies in § 503.43(c)(3) and (d)(5) after September 3, 1999:

(i) The performance test shall be conducted under representative sewage sludge incinerator conditions at the highest expected sewage sludge feed rate within the design capacity of the sewage sludge incinerator.

(ii) The permitting authority shall be notified at least 30 days prior to any performance test so the permitting authority may have the opportunity to observe the test. The notice shall include a test protocol with incinerator operating conditions and a list of test methods to be used.

(iii) Each performance test shall consist of three separate runs using the applicable test method. The control efficiency for a pollutant shall be the arithmetic mean of the control efficiencies for the pollutant from the three runs.

(4) The pollutant limits in § 503.43 (c) and (d) of this section shall be submitted to the permitting authority no later than 30 days after completion of the air dispersion modeling and performance test.

(5) Significant changes in geographic or physical characteristics at the incinerator site or in incinerator operating conditions require new air dispersion modeling or performance testing to determine a new dispersion factor or a new control efficiency that will be used to calculate revised pollutant limits.

[58 FR 9387, Feb. 19, 1993, as amended at 64 FR 42572, Aug. 4, 1999]
The 1 case that cites 40 C.F.R. § 503.43 most heavily, weighted by court and treatment. RelevanceNewestTreatment
1
GREENNat'l Ass'n of Clean Water Agencies v. Env't Prot. Agency, 734 F.3d 1115 (D.C. Cir. 2013).
cites § 503.43 2×cited by 33 cases
Where it cites § 503.43
“These regulations include a requirement that incinerators comply with Clean Air Act emission standards for beryllium and mercury, see 40 C.F.R. § 503.43 (a)-(b), and set limits for the average daily concentrations of lead, cadmium, and other metals in the sewage sludge that is…”
The case’s holding
An agency must provide a reasoned explanation for its statistical estimations and courts may not accept post hoc rationalizations for agency action.
Later courts cite it for
“epa did not state this rationale in the rulemaking, and we cannot 'accept appellate counsel's post hoc rationalizations for agency action.” · 3 citing courts

The flag is Syfertize’s treatment of the citing case itself, not of the statute. “Where it cites” is the passage in the opinion; the holding is a summary of the whole case and may concern another point. Annotations are extracted automatically from the opinions in the Syfert caselaw corpus.

By subsection

Courts have not cited this section by subsection, so its cases are not split up here. The Leading cases tab lists the cases that cite it most heavily.

Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.