Insulation resistance tests, wires in trunking and cables

Edition and currency
eCFR text as of Sept. 29, 2026. The text is the edition Syfert holds; for a past event, check the version in force on that date.
Other sources
CURRENTeCFR text as of Sept. 29, 2026 cited 2003 2citing cases
At a glance

Courts have cited this section in 2 opinions since 2003.

(a) Insulation resistance tests shall be made when wires or cables are installed and at least once every ten years thereafter.

(b) Insulation resistance tests shall be made between all conductors and ground, between conductors in each multiple conductor cable, and between conductors in trunking. Insulation resistance tests shall be performed when wires, cables, and insulation are dry.

(c) Subject to paragraph (d) of this section, when insulation resistance of wire or cable is found to be less than 500,000 ohms, prompt action shall be taken to repair or replace the defective wire or cable. Until such defective wire or cable is replaced, insulation resistance tests shall be made annually.

(d) A circuit with a conductor having an insulation resistance of less than 200,000 ohms shall not be used.

(e) Required insulation resistance testing that does not conform to the required testing schedule of this section shall be completed in accordance with the following schedule:

(1) Not less than 50% by the end of calendar year 1996;

(2) Not less than a total of 75% by the end of calendar year 1997; and

(3) One hundred percent by the end of calendar year 1998.

The 2 cases that cite 49 C.F.R. § 234.267 most heavily, weighted by court and treatment. RelevanceNewestTreatment
1
GREENBronson v. Umphries, 138 S.W.3d 844 (Tenn. Ct. App. 2003).
cites § 234.267 8×cited by 17 cases
Where it cites § 234.267
“11 Appellants also assert that the trial court erred in refusing to charge the jury concerning the substance of 49 C.F.R. § 234.267 , which provides as follows: (a) Insulation resistance tests shall be made when wires or cables are installed and at least once every ten years…”
Later courts cite it for
“the doctrine of spoliation of evidence permits a court to draw a negative inference against a party that has intentionally, and for an improper purpose, destroyed, mutilated, lost, altered, or concealed evidence.” · 4 citing courts
2
NO FLAGThomas Bronson v. Horace Umphries v. Norfolk Ry., No. W2002-01260-COA-R3-CV (Tenn. Ct. App. May 21, 2003).
cites § 234.267 6×cited by 0 cases
Where it cites § 234.267
“11 Appellants also assert that the trial court erred in refusing to charge the jury concerning the substance of 49 C.F.R. §234.267 , which provides as follows: (a) Insulation resistance tests shall be made when wires or cables are installed and at least once every ten years…”

The flag is Syfertize’s treatment of the citing case itself, not of the statute. “Where it cites” is the passage in the opinion; the holding is a summary of the whole case and may concern another point. Annotations are extracted automatically from the opinions in the Syfert caselaw corpus.

By subsection

Courts have not cited this section by subsection, so its cases are not split up here. The Leading cases tab lists the cases that cite it most heavily.

Enactment and amendments

Syfert holds no separate history line for this section. Where this code prints a source or history note, it appears with the text, usually at the end.

Versions

Edition shown: eCFR text as of Sept. 29, 2026. Syfert holds no earlier or later version of this section.

C.F.R. Home  |  Search C.F.R.  |  Search cases for this section  |  syfert.com